Small Range Differential Pressure Sensors - tc168

tc 168 1 02

This digital differential pressure meter is designed with imported pressure sensors, high accuracy ADC and low power consumption MCU, professional high accuracy, high range, high resolution, large screen display, with room temperature measurement. A single channel can quickly measure the current detection pressure value (relative to the current atmospheric pressure), and through dual channels can simultaneously detect the difference in pressure between the two detection ports (P1-P2).

TC 168 6
  • ℃/℉display
  • ℃/℉conversion
  • Pressure value display
  • Hold data mode
  • Data storage function
  • Data search function
  • Maximum minimum data mode
  • Automatic shutdown function

This product is widely used in natural gas pipelines, air-conditioning refrigeration and ventilation systems, mechanical hydraulics, plastic molding, ceramic products, biopharmaceutical molding, mining area pressure detection, petrochemical refining, gas, liquid, and production industrial equipment pressure detection.

Unit of MeasurementPsi, kg-cm², ozin²,bar , mbar, kPa inHg, mmHg, inH2O, ftH2O, cmH2O, Pa UnitRangeResolution
Accuracy±0.3% FSO kPa±20.680.001
Repeatability±0.2% (MAX±0.5%FSO) Psi±2.9990.001
Linearity/Hysteresis±0.29%FSO Kg-cm²±0.2100.001
Measurement Rate0.5 s Ozin²±47.990.01
Data Storage100 Groups Bar±0.2060.001
Low Battery Indicator6.8V show low battery symbol mBar±206.80.1
Automatic Shutdown ConditionsNo operation for 15 minutes inHg±6.1060.001
Positive Pressure Range Display Err 0 mmHg±151.10.1
Over Negative Pressure Range DisplayErr 1 InH2O±83.020.01
Working Temperature0~50℃(32~122℉) ftH20±6.9180.001
Working Power9V battery cmH2O±210.80.1
Physical Dimension164X71X35mm Pa±99991
Weight300g    

20220108095357

                                                                                          1.Power on/off Button                 7.LCD Display
                                                                                          2.ºC/ºF Button                              8.Tube Connector (+)
                                                                                          3.HOLD Button                              9.Tube Connector (-)
                                                                                          4.UNITS Button                           10.Label position
                                                                                          5.DIF Button                                 11.Battery Cover
                                                                                          6.MAX Button

  • Carbon dioxide concentration
  • Temperature
  • Humidity
  • Public places

The densely populated place such as meeting room, classroom, exhibition hall, hospitals, department stores, bars, hotel, air port, railway station and entertainment hall, etc. the carbon dioxide detector may be used for ventilation control and environment quality monitoring So, it is used to guarantee body health.

  • Agriculture

The carbon dioxide may be used for plant photosynthesis. Therefore, it is widely used for agriculture. The air fertilizer with proper concentration may improve output of agricultural crops. When the concentration of carbon dioxide is not sufficient, air fertilizer may be used. It will give great help for whether the vegetable growth or improvement of vegetable.

  • Animal husbandry

The air quality concerns healthy growth of animals. If the air is turbid for a long time and the concentration of carbon dioxide is high and ventilation is not provided, the animal will get ill or epidemic disease may burst out. Therefore, installation of carbon dioxide detector at livestock farm may prevent occurrence of animal epidemics.

  • Industry

The carbon dioxide detector is widely used in the Industry such as wastewater treatment, factory building, workshop, temperature, cleaning room, production safety and all types of Industries. Especially, it is very necessary to monitor the carbon dioxide in borehole operation. The carbon dioxide detector is used generally in metal processing, paper pulp and paper making, cleaning and solvent extraction as well as lower temperature cleaning and carbon dioxiderelevant Industry.

Temperature accuracy±3%
CO2 measurement range370-9999 PPM
Concentration Resolution1 PPM
Concentration Accuracy±3% of readings of ±40PPM
Temperature measurement range-20℃ ~ +60℃
Humidity measurement range0-99% RH
Dimension80*80*55 mm
Weight126g
BatteryBuilt-in 1500mAh lithium battery
Power supply5V/ USB
Working time≥8 hours
Humidity accuracy±5% RH

PRODUCT FEATURES

ULTRA PRECISION SENSOR

The detection error is only ±3% of readings of ±40PPM

Auto Calibration function

It will always keep a high measurement accuracy to the detector

Small LCD HD display

Low power consumption with simple and clear system instructions

SCIENTIFIC & PORTABLE DESIGN

Exquisite structural design provide us the scientific basis for detecting

Custom options available

Design corresponding according to different requirements, such as language

portable USB charging

Universal USB port supports fast charging of devices

TC 168 1
TC 168 2
TC 168 3
TC 168 4
TC 168 5
TC 168 6 1
Open chat
Need help?
Hello, how can I help you?
Do not hesitate to contact us. We have our own online shop as well.
So, if you want to buy 1 unit only, that's ok for us as well.